Model reference
Whirlpool YKFEG500ESS7
Range
8 documents23 error codes13 service modes
Available documentation
Tech Sheet
- Tech Sheet28 pg
- Tech Sheet W11401743 REVA2 pg
- Tech Sheet - W11401743 - Rev B2 pg
Bulletin
- Installation Pointer - W11663212 - Rev B - New Terminal Block for Tulsa FSR6 pg
Tech Tip
- Oven Cleaning Quick Reference Guide2 pg
Quick Reference
- Freestanding Electric Range Quick Start Guide2 pg
- Quick Start Guide2 pg
- Freestanding Electric Range Control Guide20 pg
MyPros+ Max
Diagnose your Whirlpool YKFEG500ESS7.
- Step-by-step diagnostics from the service manual
- Test values, resistance specs, and wiring references
- Verified part numbers when replacement is needed
Start diagnosing
$29/month · Cancel anytime · Or $9.95 3-day pass · Plus applicable tax
Error codes (23)
CodeMeaning
EEPROMEEPROM communication error.F1 E5Sensor out of range.F1 E7PCB thermistor open or shorted.F1 E9WIDE queue full.F1-E0EEPROM communication error.F2 E0Keypad disconnected.F2 E1Stuck key.F2 E2Cancel key error.F2E0Keypad disconnected from the oven control.F2E1Stuck key detected on the control panel.F2E2Cancel key error.F3-E0Main oven temperature sensor open or shorted.F3-E2Warming drawer sensor open or shorted.F3E0Main oven sensor open or shorted.F3E2Warming drawer sensor open or shorted.F5-E0Door and door switch do not agree (Clean modeF5E0Door position and door switch do not agree (Clean modeF6 E1Over temperature during cook cycle.F6 E3Over temperature in warming drawer.F6E1Over temperature condition during cook mode.F6E3Over temperature condition in the warming drawer.F9-E0Mis-wired house or range.F9E0Mis-wired house or rangeService modes (13)
- Auto TestEnter Diagnostics Mode (CANCEL > CANCEL > START), then press up arrow/'+'/3 to scroll to 'AUTO TEST'
- CONTROL RESETFrom Diagnostics Mode, scroll to step 6 'CONTROL RESET'.
- Diagnostics / Auto Test1
- Diagnostics Mode (Service Mode)Press CANCEL > CANCEL > START
- DISPLAYFrom Diagnostics Mode, scroll to step 5 'DISPLAY'.
- ENG MODEFrom Diagnostics Mode, scroll to step 2 'ENG MODE'
- FAULTSFrom Diagnostics Mode, scroll to step 7 'FAULTS'.
- RELAY USAGEFrom Diagnostics Mode, scroll to step 8 'RELAY USAGE'.
- Temperature AdjustmentPress OPTIONS until 'Temp Calib' is displayed
- TEST MODEFrom Diagnostics Mode, scroll to step 3 'TEST MODE'
- TEST ON (Relay Checks)Displayed upon entry into Diagnostics Mode (CANCEL > CANCEL > START)
- USAGEFrom Diagnostics Mode, scroll to step 1 'USAGE'.
- VERSIONFrom Diagnostics Mode, scroll to step 4 'VERSION'.
Full entry steps, exit procedures, and test sequences are available in Max.