Model reference
Sub-Zero ID-36C
Refrigerator
4 documents94 error codes11 service modes
Available documentation
Service Manual
- Service Manual IW-30CI65 pg
- Sub-Zero Service Manual: IW-30CI (Vol. 7) — Service Manual5 pg
- Sub-Zero Service Manual: Integrated Drawer — Service Manual199 pg
Parts Manual
- Sub-Zero Parts Manual: Integrated Drawers — Parts Manual57 pg
MyPros+ Max
Diagnose your Sub-Zero ID-36C.
- Step-by-step diagnostics from the service manual
- Test values, resistance specs, and wiring references
- Verified part numbers when replacement is needed
Start diagnosing
$29/month · Cancel anytime · Or $9.95 3-day pass · Plus applicable tax
Error codes (94)
CodeMeaning
10 0 00Condenser thermistor open circuit detected.10 0 01Condenser thermistor short circuit detected.10 0 02Condenser thermistor unstable signal.10 1 00An open Zone 1 cabinet thermistor.10 1 01Short in Zone 1 cabinet thermistor.10 1 02Zone 1 cabinet thermistor is unstable.10 1 10An open Zone 1 evaporator thermistor.10 1 11Short in Zone 1 evaporator thermistor.10 1 12Zone 1 evaporator thermistor is unstable.10 2 00An open Zone 2 cabinet thermistor.10 2 01Short in Zone 2 cabinet thermistor.10 2 02Zone 2 cabinet thermistor is unstable.10 2 10An open Zone 2 evaporator thermistor.10 2 11Short in Zone 2 evaporator thermistor.10 2 12Zone 2 evaporator thermistor is unstable.10 3 00An open Zone 3 cabinet thermistor.10 3 01Short in Zone 3 cabinet thermistor.10 3 02Zone 3 cabinet thermistor is unstable.10 3 10An open Zone 3 evaporator thermistor.10 3 11Short in Zone 3 evaporator thermistor.10 3 12Zone 3 evaporator thermistor is unstable.10 7 00An open ambient thermistor on the control board.10 C 00An open condenser thermistor.10 C 01Short in condenser thermistor.10 C 02Unstable condenser thermistor.10 F 00An open Zone 4 cabinet thermistor.10 F 01Short in Zone 4 cabinet thermistor.10 F 02Zone 4 cabinet thermistor is unstable.10 F 10An open Zone 4 evaporator thermistor.10 F 11Short in Zone 4 evaporator thermistor.View all 94 error codes
10 F 12Zone 4 evaporator thermistor is unstable.15 1 00Zone 1 compressor relay stuck open15 1 01Zone 1 compressor relay stuck closed15 2 00Zone 2 compressor relay stuck open15 2 01Zone 2 compressor relay stuck closed15 3 00Zone 3 compressor relay stuck open15 3 01Zone 3 compressor relay stuck closed15 4 00Defrost relay is stuck open, caused by no voltage feedback through the defrost…15 4 01Defrost relay is stuck closed, caused by voltage feedback through the defrost…15 C 00AC condenser fan relay stuck open15 C 01AC condenser fan relay stuck closed15 U 00Water valve no current detected during activated call for water or dispense.15 U 01Water valve current still detected after valid dispense or ice maker fill20 2 00Defrost bi-metal stuck open.20 2 01Defrost bi-metal stuck closed.20 2 05Defrost bi-metal mis-wire with normal temps20 2 06Defrost bi-metal mis-wire with overheat20 2 50Defrost heater open circuit.20 4 50Defrost heater has failed open.30 8 05Icemaker no water valve input signal35 1 00Zone 1 evaporator fan is open.35 1 33Zone 1 fan speed is slower than setting.35 1 34Zone 1 fan speed is faster than setting.35 2 00Zone 2 evaporator fan is open.35 2 33Zone 2 fan speed is slower than setting.35 2 34Zone 2 fan speed is faster than setting.35 3 00Zone 3 evaporator fan is open.35 3 33Zone 3 fan speed is slower than setting.35 3 34Zone 3 fan speed is faster than setting.35 A 00Air filter fan open circuit.35 C 00Condenser fan is open.35 C 33Condenser fan speed is slower than setting.35 C 34Condenser fan speed is faster than setting.40 1 00Zone 1 stepper current fault40 1 09Zone 1 house alarm40 1 40Zone 1 excessive compressor runtime.40 1 87Zone 1 stepper cooling fault40 2 00Zone 2 stepper current fault40 2 09Zone 2 house alarm40 2 40Zone 2 excessive compressor runtime.40 2 87Zone 2 stepper cooling fault40 3 09Zone 3 house alarm40 3 40Zone 3 excessive compressor runtime.40 4 40Zone 4 excessive compressor runtime.40 9 40Dispenser excessive runtime40 b 00Baffle stepper current fault.40 b 87Baffle cooling/position fault.45 1 00Open in Zone 1 light circuit.45 1 01Short in Zone 1 light circuit.45 2 00Open in Zone 2 light circuit.45 2 01Short in Zone 2 light circuit.45 3 00Open in Zone 3 light circuit.45 3 01Short in Zone 3 light circuit.45 F 00Open in Zone 4 light circuit.45 F 01Short in Zone 4 light circuit.90 5 80No UIM (User Interface Module) communications.90 H 80High voltage micro (CCM) no communication90 H 82High voltage micro (CCM) partial communications90 H 83High voltage micro (CCM) bad communications90 H 84High voltage micro (CCM) initialization fault.95 1 00Door #1 excessive open time.95 2 00Door #2 excessive open time.95 3 00Door #3 excessive open time.95 F 00Door #4 excessive open time.
Service modes (11)
- Clear Faults["Enter the Service Options Menu (Settings > Service Options > Enter Password).","Tap Clear…
- Current Temperatures["Enter the Service Options Menu (Settings > Service Options > Enter Password).","Tap Temps.","Tap…
- Manual Component Activation["Enter the Service Options Menu (Settings > Service Options > Enter Password).","Tap Manual…
- Manual Defrost["Enter the Service Options Menu (Settings > Service Options > Enter Password).","Tap…
- Model Configuration["Enter the Service Options Menu (Settings > Service Options > Enter Password).","Tap…
- Sabbath Mode["Tap Settings.","Tap Sabbath mode.","Touch and hold the screen for 10 seconds to enable Sabbath…
- Service Options1
- Service Options Menu["Tap Settings icon on the Home screen.","Tap Service Options icon.","Enter the password for the…
- Showroom Mode["On the Home screen, tap the arrow icon to go to Options screen.","Tap Settings.","Tap Service…
- Temperature Log["Enter the Service Options Menu (Settings > Service Options > Enter Password).","Tap Temp…
- Zone Temperature Offset["Enter the Service Options Menu (Settings > Service Options > Enter Password).","Tap Offset.","Tap…
Full entry steps, exit procedures, and test sequences are available in Max.
Related Sub-Zero refrigerator models
76,000+ service documents · 19,000+ error codes · 100+ brands
Get Started$29/month · Cancel anytime · Or $9.95 3-day pass · Plus applicable tax