Model reference
Maytag MGT8775XS00
Range
6 documents30 error codes18 service modes
Available documentation
Tech Sheet
- techsheet w10311749 reva32 pg
Service Manual
- Troubleshooting Gas and Electric Freestanding Range Electronic Controls70 pg
Service Flash
- Technical Service Pointer - W10418467 (Gas Smell)3 pg
Other
- DP W10367616 LP instruct final2 pg
Installation Guide
- Installation Instructions40 pg
- Instruction Sheet1 pg
MyPros+ Max
Diagnose your Maytag MGT8775XS00.
- Step-by-step diagnostics from the service manual
- Test values, resistance specs, and wiring references
- Verified part numbers when replacement is needed
Start diagnosing
$29/month · Cancel anytime · Or $9.95 3-day pass · Plus applicable tax
Error codes (30)
CodeMeaning
E0 F1EEPROM communication error.E0 F3Main oven temperature sensor open or shorted (upper cavity).E1 F1Upper RTD uncalibrated.F1Control failure or UL A/D error(s) detected in the control board.F1 E*Control board failure (all F1 sub-codes indicate control fault).F1 E0EEPROM communication error.F1 E1Upper RTD (resistance temperature detector) uncalibrated.F1 E2Lower RTD uncalibrated.F1 E5Sensor usage out of range.F1 E7PCB thermistor/sensor open or shorted.F1 E9WIDE queue full.F2Shorted/stuck key detected on the control keypad.F2 E0Keypad disconnected.F2 E1Stuck key.F2 E2Stuck key.F3Oven sensor opened or oven sensor shorted.F3 E0Main oven temperature sensor open or shorted (upper cavity).F3 E1Main oven temperature sensor open or shorted (lower cavity).F3 E2Warming drawer temperature sensor fault.F5 E0Door and latch switches do not agree during Clean mode.F5 E1Door latch not operating during Clean mode.F5 E2Door switch fault.F6Control communication error.F6 E*Control communication failure.F6 E0Lost communications.F6 E1Over temperature during cook mode (runaway temperature).F6 E2Over temperature during clean mode (runaway temperature).F6 E3Over temperature in warming drawer (runaway temperature).F9House miswiredF9 E0Product is mis-wired.Service modes (18)
- Diagnostics ModePress CANCEL > CANCEL > START within 5 seconds.
- Diagnostics Mode (includes Semi Automatic Test)["Press CANCEL, then CANCEL, then START within 5 seconds.","If control does not enter Diagnostics…
- Faults (view stored fault codes)1
- LCC Diagnostic Mode (LCC90/LCC95/LCC180)["Press CANCEL, CANCEL, START in sequence.","Press TEMP/TIME '+' key to cycle through diagnostic…
- LCC Diagnostic Mode (LCC90/LCC95/LCC180/LCC190 - TEMP/TIME controls)["Press CANCEL, CANCEL, START","Press TEMP/TIME '+' key to step through diagnostic screens:","First…
- LCC190 Diagnostic Mode (Self Clean, Convection models)["Press CANCEL, CANCEL, START in sequence.","Press TEMP/TIME or TEMP/HOUR '+' key to cycle through…
- MRC Diagnostic Mode["Press CANCEL, CANCEL, START in sequence.","Press TEMP/TIME '+' key to cycle through diagnostic…
- MRC Diagnostic Mode (Fan/True Convection Electric - Oven Light entry)["Press CANCEL, CANCEL, START in sequence.","Press TEMP/TIME '+' key to cycle through diagnostic…
- MRC Diagnostic Mode (MRC controls with OVEN LIGHT entry - Fan/True Convection Electric models)["Press CANCEL, CANCEL, START
- MRC Diagnostic Mode (MRC controls with TEMP/TIME keys)["Press CANCEL, CANCEL, START
- MRC II Diagnostic Mode (number '3' key navigation - KitchenAid models)["Press CANCEL, CANCEL, START (or OFF/Off/START)
- MRC II Diagnostic Mode (Number 3 key entry - KitchenAid models)["Press OFF/OFF/START or CANCEL/CANCEL/START in sequence.","Press the number '3' key to cycle…
- MRC II Diagnostic Mode (TEMP/TIME '+' key navigation)["Press CANCEL, CANCEL, START
- MRC II Diagnostic Mode (TEMP/TIME entry)["Press CANCEL, CANCEL, START in sequence.","Press TEMP/TIME '+' keypad to cycle through diagnostic…
- Semi Automatic Test1
- Semi Automatic Test Mode["Enter Diagnostics Mode first (CANCEL>CANCEL>START within 5 seconds).","Press TEMP/TIME '+' or '-'…
- Temperature Calibration["Press SETTINGS/OPTIONS until 'Temp Calib' is highlighted.","Follow instructions to see the…
- Test Mode["Enter Diagnostics Mode first (CANCEL>CANCEL>START within 5 seconds).","Press TEMP/TIME '+' or '-'…