Error code reference

Samsung Heat Pump Error Codes

146 error codes documented with diagnostic procedures.

Have your model number? Get codes specific to your unit.
AxIndoor unit EVAP IN sensor breakaway error (x = indoor unit address).BxElectronic expansion valve open error (x = indoor unit address)ChCompressor preheating in progressCxElectronic expansion valve open error for xth indoor unitDxOPEN/SHORT error of EVAP IN sensor in indoor unit (x = indoor unit address).E1System down due to communication error after completion of trackingE101Communication error between the indoor unit and the wired remote panel (PAC).E121Indoor unit room tempE122Indoor unit EVAP IN Sensor open or short errorE123Indoor unit EVAP OUT Sensor open or short errorE124Communication error sends from indoor unitE128Indoor unit EVA IN sensor breakawayE129Indoor unit EVA OUT sensor breakawayE151Indoor unit EEV open failure (When 2nd detection)E152Indoor unit EEV close failure (When 2nd detection)E153Indoor unit float switch detectionE154Indoor unit fan errorE161Mixed operation error (operate heat & cool mode at same time)E162EEPROM errorE163Option setting errorE165Electric heater discharge temperature protect errorE166No fan error related to the electric heaterE167S/W setup error in peripheral control device using optionE181The 2nd MCU SOL V/V cooling/heating opening at the same timeE2Tracking errorE201Tracking error-mismatch between the number of indoor units detected during communication…E202Communication error between indoor and outdoor unit (When not received in every room…E203Communication error between main of outdoor unit and sub MICOM or between unitsE210Communication error between the outdoor unit and MCUE211Indoor unit connected with confluence kit without continuity.E212Indoor unit connected with confluence kit and setting address was over lapped more than 3.E221Outdoor temperature sensor OPEN/SHORT error.E223COND-OUT MAIN temperature sensor error OPEN/SHORT.E226OUT-TEMP temperature sensor breakawayE231COND-OUT MAIN TEMP sensor error OPEN/SHORT.E236COND-OUT SUB 1 TEMP sensor error OPEN/SHORT.E241COND-MID sensor breakaway of outdoor unit.E251PWM DISCHARGE TEMP sensor error OPEN/SHORT; detected when the outdoor temperature is over…E261Digital discharge sensor breakaway.E262Compressor discharge temperature sensor breakaway-difference between digital compressor…E263Compressor discharge temperature sensor breakaway-difference between digital compressor…E264Compressor discharge temperature sensor breakaway-difference between digital compressor…E265Sump-main breakaway error.E266Sump Sub 1 breakaway error.E267Sump Sub 2 breakaway error.E268Sump Sub 3 breakaway error.E269Suction breakaway error.E271SUMP TEMP DIGITAL sensor error OPEN/SHORT; detected when the outdoor temperature is over…E276SUMP TEMP FIXED 1 sensor error OPEN/SHORT; detected when the outdoor temperature is over…E277SUMP TEMP FIXED 2 sensor error OPEN/SHORT; detected when the outdoor temperature is over…E278SUMP TEMP FIXED 3 sensor error OPEN/SHORT; detected when the outdoor temperature is over…E291High pressure sensor error OPEN/SHORTE296Low pressure sensor error OPEN/SHORT, detected when the compressor is ready to operate…E3Indoor unit float switch errorE301High pressure sensor breakaway.E306Low pressure sensor breakaway.E308Suction TempE312Main cooling solE3134-Way v/v operation errorE4Setting error of option switch in indoor unitE401Outdoor unit freezing detection 1.E402Outdoor unit freezing detection 2.E403Compressor down by indoor unit freezing protection control.E404Outdoor unit overload 1 protection control error.E405Outdoor unit overload 2 protection control error.E406Outdoor unit overload 3 protection control error.E407Compressor down by high pressure sensor protection control 1.E408Compressor down by high pressure sensor protection control 2.E409Compressor down by high pressure sensor protection control 3.E410Compressor down by low pressure sensor protection control 1.E411Compressor down by low pressure sensor protection control 2.E412Compressor down by low pressure sensor protection control 3.E413Outdoor unit SUMP DOWN 1 protection control.E414Outdoor unit SUMP DOWN 2 protection control.E415Outdoor unit SUMP DOWN 3 protection control.E416Outdoor unit discharge temperature 1 protection control.E417Outdoor unit discharge temperature 2 protection control.E418Outdoor unit discharge temperature 3 protection control.E419Outdoor unit EEV open 1 self diagnosis error.E420Outdoor unit EEV open 2 self diagnosis error.E421Outdoor unit EEV open 3 self diagnosis error.E422Outdoor unit EEV close 1 self diagnosis error.E423Outdoor unit EEV close 2 self diagnosis error.E424Outdoor unit EEV close 3 self diagnosis error.E425Detection of reverse phase or missing phase of 3-phase powerE426Outdoor unit reverse phase detection 2 error.E427Outdoor unit reverse phase detection 3 error.E428Outdoor unit compression rate 1 error (compression ratio over 8.5 for more than 5…E429Outdoor unit compression rate 2 error.E430Outdoor unit compression rate 3 error.E440Forbid heat mode operation when outdoor temperature is over 30°C.E441Forbid cooling mode operation when outdoor temperature below -5°C.E442Forbid an operation during heat mode with refrigerant charging operation when outdoor…E452Instant power off (disappear when compressor run).E471Indoor unit floating switch error (2nd detection)E5Setting error of option switch for peripheral equipment controlE551Defrosting operation (not an error).E552Low discharge pressureE553Equability (oil leveling) operationE554Loading Failure; full leakage of refrigerant of outdoor unit.E601Communication error between wired remote controller and indoor unit.E602Communication error between master wired remote controller and slave wired remote…E603Communication error between 7 day scheduler and wired remote controller.FxSimultaneous breakaway of indoor unit EVAP IN and EVAP OUT sensor (x = indoor unit…G2Total leakage of refrigerant in outdoor unit or compressor loading failure.G3Breakaway of COND MID sensor in outdoor unit.G4Breakaway of OIL temperature sensor (detected once or more times)G5Breakaway of SUCTION sensorG6Breakaway of fixed compressor discharge sensor (detected once or more times)G7Outdoor unit freezing detection (indoor unit heat exchanger below -4°C for over 40…G8No heating operationG9OPEN/SHORT error of EVAP OUT sensor in indoor unit (x = indoor unit address).P0System down due to high temperature of discharge sensor (discharge temperature exceeding…P1System down due to high temperature of COND sensor (condensate temperature of compressor…P2SUMP COMP DOWNP3System down due to low pressure switch detection (low pressure lower than 1.2 kg/cm2G…P4Reverse phase or open phase errorP5System down due to frozen heat exchangerP6Error of momentary power failureP7Error of momentary power failureP701Float switch detection error (low level riskP702Indoor unit EEV closing error (low level risk).P703Indoor unit EEV opening error (low level risk).P704MCU Solenoid valve failure (low level risk).P8Compressor down due to protection control of low pressure sensor (low pressure less than…P9Compressor down due to low pressure sensor protection control (less than 3 kg/cm²G in…PACompressor down due to protection control of condensation ratio (compression ratio…qxOPEN/SHORT error of room sensor in indoor unit (x = indoor unit address).rxCooling operation forbidden when outdoor temperature is below -5°C (flickering display).sxHeating operation forbidden when outdoor temperature is over 30°C, or charging…t1Error of outdoor temperature sensor (OPEN/SHORT)t2Error of condenser temperature sensor (OPEN/SHORT)t3Error of PWM discharge temperature sensor (OPEN/SHORT)t4Error of liquid refrigerant pipe (COND OUT) temperature sensor (OPEN/SHORT)t5Error of oil temperature sensor (OPEN/SHORT)t6Error of suction temperature sensor (OPEN/SHORT)t7Error of high pressure sensor (OPEN/SHORT)t8Error of low pressure sensor (OPEN/SHORT)t9Error of fixed compressor discharge sensor (OPEN/SHORT)toOver 30°C when heatingtuBelow -5°C when coolingU200Communication error between outdoor unit main and sub MICOM or communication error…U201Communication error between outdoor unit main and sub MICOM or between outdoor units.U202Communication error between outdoor unit main and sub MICOM or between outdoor units.U203Communication error between outdoor unit main and sub MICOM or between outdoor units.vxIndoor unit fan motor starting error (x = indoor unit address).

Get the full diagnostic procedure for any code

Step-by-step tests, expected values, wiring diagram references, and verified part numbers.

Get Started $9.95 3-day pass

$29/month for all brands and Max diagnostics, with 70 Max messages a day. Plus applicable tax.