Error code reference

Maytag Dryer Error Codes

226 error codes documented with diagnostic procedures.

Have your model number? Get codes specific to your unit.
0No code present (no fault detected).00No diagnostic codes available-displayed when there are no stored diagnostic codes.01Thermistor short sensed02Thermistor open sensed03Door circuit failure04Possible motor transistor error06Non-volatile memory problem08Stuck key1Lower Dryer Thermistor Short Sensed10No wet clothes-sensor bar detects no wet clothes while a Sensor Dry cycle is running.11Upper Dryer Thermistor Short Sensed12Upper Dryer Thermistor Open Sensed13Upper Dryer Door Circuit Failure14Heater on and drum temperature not increasing.15Heater on and drum temp not increasing.16Thermistor possible short.17Motor thermal protector opened more than 5 times during cycle.18Motor thermal protector opened more than 5 times during cycle.2Lower Dryer Thermistor Open Sensed20Motor thermal protector opened more than 5 times during cycle.21Heater on and drum temp not increasing.22Selected dryer temperature not reached.23Dryness sensor bar possibly shorted.24Incorrect rotary switch position seen.25Rotary Switch 1 left of encoder failed at startup.26Rotary Switch 1 left of encoder failed at startup.28Rotary Switch 2 left of encoder failed at startup.3Door switch related error code; indicates a door switch issue preventing the dryer from…31Model ID Unknown, Default used; Rotary Switch 3 left of encoder failed at startup.4Possible motor transistor error-one or both motor transistors open or short-circuited…5Not used.6Non-volatile memory error-problem detected with integrity of parameters stored in EEPROM…8Stuck key88Help codeACCUDryer motor control circuit error-the control cannot determine if the motor relay is…AFRestricted/low air flow detected that may affect dryer performance.AXIAL PROBE FAULTProblem with the axial temperature sensor circuit.bCLOBad coin lockoutBURNER CONTROL FAULTGas return valve signal did not turn on before DSI purge time expired or turned on for…BURNER HIGH LIMIT FAULTThe temperature disk in the burner has opened (burner hi-limit has tripped).BURNER IGNITION CONTROL FAULTNo signal to gas valve from Direct Spark Ignition (DSI) module during trial for ignition…BURNER PURGE FAULTControl detected presence of gas return signal before sending the heat signal out.C1Blocked coin 1 or coin drop control circuit failure (coin recognition and customer…CCU error (motor feedback - stacked)CCU errorCCU error (motor feedback with door open)CCU error-CCU will send this error when the motor feedback circuit is sensing voltage…CHECK CONTROL BOARD FUSE #2Main fuse (fuse 2) on the Phase 7 control board has opened; 24V control power fuse rated…CLEAN LINTLint cleaning frequency timer has expired; lint drawer must be opened for at least 15…Coin 1Coin 1 failure. For PN modelsCoin 2 FailureCoin 2 failure detected.dUI Microprocessor is not able to read or verify EEPROMd (blocked coin 1)Blocked coin 1 or coin drop UI control circuit failured (blocked coin 2)Blocked coin 2 or coin drop UI control circuit failured (CCU no comm from UI)CCU is not receiving communications from UId (low voltage)Voltage detected below 90 VAC for 8 seconds.d (no debit comm)Not receiving communications from installed debit card reader in Enhanced (Generation 2)…d (shorted)Exhaust thermistor shortedd (UI EEPROM CRC)UI EEPROM memory is a CRC failured (UI micro EEPROM)UI Microprocessor is not able to read or verify EEPROMd (UI no comm from CCU)UI is not receiving communications from CCUd1Upper dryer door sense error on control board or due to line interference (upper dryer…d12Motor sense error on control board or due to power line interference (single dryer)d13Blocked coin 2 or coin drop control circuit failure (coin recognition and price display…d14Upper dryer motor sense circuit error on control board or due to power line interference…D15Lower Burner Return Voltage Fault (stack dryers only)-same as D23 but for the lower…D16Gen 2 Card Reader Communication Fault-no health check received from the Gen 2 debit card…d17Lower dryer door sense error on control board or due to power line interference (stacked…D18Axial Probe Fault-the axial thermistor is reading a temperature out of its normal…D19Exhaust High Temp Fault-the exhaust probe detects a tumbler temperature 20°F above the…d2Exhaust thermistor open, temperature drops below 18°F (>50 kΩ) for 1 minute in Run mode…D20Sail Switch Open Fault-the sail switch did not close within 10 seconds at startup, or…D21Sail Switch Closed Fault-at cycle startup the sail switch did not open within 10 seconds…D22Latched Heat Relay Fault-the heat relay contacts are detected as closed when the heat…D23Burner Return Voltage Fault-the burner return signal is active but heat relay contacts…d3UI is not receiving communications from CCU; cycles and price display disabled while…d4Dryer motor control circuit error (cycles and price display disabled until diagnostic…d5Blocked coin 1 or coin drop UI control circuit failure (coin recognition and customer…D6Lower Exhaust Probe Fault (stack dryers only)-same as D17 but for the lower pocket.D7Lower Sail Switch Closed Fault (stack dryers only)-same as D21 but for the lower pocket.D8Lower Latched Heat Relay Fault (stack dryers only)-same as D22 but for the lower pocket.d9Low voltage detected; less than 90 volt AC for 8 seconds (machine functional).dCDoor circuit failure-invalid state for more than 256 milliseconds (display fault code).DISCONNECTED WATER VALVES.A.F.EdODoor Open ErrordonEDrying and cooling cycles complete or dryer is in anti-wrinkle cycle.dOOrDoor or lint drawer switch circuit is open, indicating a fault in the door switch circuit…dSFLTemperature sensor connection fault displayed when power is reestablished after sensor…E1Radiant Sensor Fault Count-gas dryer attempted to turn on burner but never received a…E2Burner Igniter Fault Count-gas dryer received 120V burner return signal but it did not…E3User interface or software mismatch (key switch or software mismatch); only appears in…E4Lower Radiant Sensor Fault Count (stack dryers only)-same as E1 but for the lower pocket.E5Lower Burner Igniter Fault Count (stack dryers only)-same as E2 but for the lower pocket.E6Lower Exhaust High Limit (stack dryers only)-same as E3 but for the lower pocket.E7Bad Coin Count (Coin 1)-count of all bad coin occurrences detected from coin input 1.E8Bad Coin Count (Coin 2)-count of all bad coin occurrences detected from coin input 2.E9Forward Rotation Sensor Fault Count-count of forward rotation sensor faults on reversing…EAReverse Rotation Sensor Fault Count-count of reverse rotation sensor faults on reversing…EdNot receiving communications from installed debit card reader in Enhanced (Generation 2)…EE PROM FAULT ###Error in memory location; the ### indicates the specific location of the fault.EXHAUST HIGH TEMP FAULTOverheating detected; temperature sensor input showed steady gradual increase to a known…EXHAUST HIGH-LIMIT FAULTBasket (tumbler) safety over-temperature switch has opened.EXHAUST PROBE FAULTProblem with the exhaust temperature sensor circuit.FDryer motor control circuit errorF-01Primary control failure in the machine control electronics.F-02Stuck button or user interface mismatch (keypad/user interface failure)F-2Low temperature sensed (40° below zero); open in thermistor circuit or room temperature…F-22Exhaust thermistor open, temperature drops below 18°F (>50 kΩ) for 1 minute in Run mode…F-23Exhaust thermistor shorted, temperature above 250°F (<500Ω) for 1 minute in Run mode, or…F-24Inlet thermistor is open (only appears in diagnostic test mode, electric models only).F-25Inlet thermistor has shorted (only appears in diagnostic test mode, electric models only).F-26Motor drive system failure.F-28Moisture sensor strip is openF-29Moisture sensor strip has shortedF-3High temperature sensed (above 180°F); possible short circuit in thermistor circuit makes…F-30Restricted airflow condition detected (only appears in diagnostic test mode, electric…F-4Motor transistor on board failure; dryer is inoperative and can occur only on start up.F-50No voltage detected at the water valve relay (only appears in diagnostic test mode, steam…F-9Low voltage (below about 95 volts); dryer will operate and fault code is not displayed…F:01Primary control failure.F:02Stuck button or user interface mismatch (appears ONLY in Diagnostic Test Mode).F:20No voltage detected at the heater relay (appears ONLY in Diagnostic Test Mode).F:22Exhaust thermistor is open.F:23Exhaust thermistor has shorted.F:24Inlet thermistor circuit is open; appears ONLY in Diagnostic Test Mode.F:25Inlet thermistor circuit is shorted; appears ONLY in Diagnostic Test Mode.F:26Motor drive system failure.F:28Moisture sensor strip is open (appears ONLY in Diagnostic Test Mode).F:29Moisture sensor strip has shorted (appears ONLY in Diagnostic Test Mode).F:30Restricted air flow condition exists (appears ONLY in Diagnostic Test Mode).F:31Low voltage condition (less than 30V) detected on L2 line (appears ONLY in diagnostic…F:50No voltage detected at the water valve relay (appears ONLY in diagnostic test mode).F:70No communication between the machine control and the console electronics.F:71No communication between the machine control and the console electronics.F:72Console electronics failure (F:72 through F:78).F:78Console electronics failure (F:72 through F:78).F0 E7Control board recognized line voltage below 90 VAC (low voltage error).F1Dryer motor control circuit error (cycles and price display disabled until diagnostic…F1 E4HMI (Human Machine Interface) fault detected.F1 E6Voltage input fault detected by the control.F1 E7ACU Voltage Input FaultF13Blocked coin 2 or control circuit failure.F14Upper dryer motor sense failure.F1E1Motor circuit is open or shorted, OR heat system is open or shorted (heat system fault…F1E3Incorrect controller installed (electric models only); ACU and/or UI part number does not…F1E5ACU parameter file missing; parameter memory invalid.F2 E1Dryer keypad is sensed pressed for 10 seconds (stuck key error); fault will auto-clear…F2 E2Upper Dryer Keypad Stuck ErrorF2E3User Interface and ACU model ID parameter mismatch caused by replacement of either UI or…F2E4UI software errorF2E5UI software errorF3E1Exhaust thermistor is open or shorted; open if temperature drops below 18°F (-8°C) (>50…F3E2Moisture sensor strip is open or shorted; this fault code only appears when in Service…F3E3Inlet thermistor open or shorted; open if temperature below 18°F (>245k ohms), shorted if…F3E4Inlet thermistor is shorted; temperature above 760°F (<20 ohms)F3E5Inlet and exhaust thermistors are both open; will occur if the P14 connector is not…F3E6Moisture sensor strip is open; this fault code will only appear when in the service…F3E7Rear moisture sensor strip is open or shorted (Maytag models only); only appears in…F4E1No voltage detected at the heater relay; this fault code appears ONLY when in the…F4E2Heater 2 failure or connector problem (electric models only); no voltage detected at the…F4E3Restricted/low air flow detected that may affect dryer performance.F4E4Low L2 voltage (less than 50V) detected at the ACU (electric models only).F4E5High limit exceeded; temperature threshold of the dryer has been exceeded, usually…F5Problem with one of the coin drop units (check mechanism and sensors); check terminal…F5 E1Lower Dryer Door Circuit ErrorF5 E6Upper Dryer Door Circuit ErrorF6 E1Communication Failure Between ACU and UICF6E2Communication errorF6E3Communication errorF7 E6Lower Dryer Motor Circuit ErrorF7 E7Upper Dryer Motor Circuit ErrorF7 E8Lower Dryer Motor Sense ErrorF7 E9Upper Dryer Motor Sense ErrorFC E1Model/Serial not ProgrammedFC E2Model and serial numbers stored in ACU and UIC do not match.FC E3Wi-Fi Connection Fault.FC E4USB FaultFC E5Software Update FailureFC E6Model Setup Export FailureFC E7Model Setup Import FailureFC E8Wi-Fi Module not responding or not connected.FEPower source frequency errorFILLNo cycle in progress; the dryer is in normal stop mode awaiting coin insertion or cycle…FLAME FAULTFlame was detected during trial for ignition but failed sometime after; this condition…FP E1Coin 1 Circuit ErrorFP E2Coin 2 Circuit ErrorFP E3Card Reader Communication ErrorGen 2 Debit CardGeneration 2 Debit Card diagnostic code.h1A temperature increase has not been detected on the lower dryer and the dryer advances to…h11A shaker assembly neutral fault has been detected; shaker relay is de-energized and the…hEHeater error-invalid heating temperature detected while running the dryer.HotOverheating condition detected; the DMC computer has detected that the dryer temperature…HPThe thermistor reading is out of range and the dryer cycle is interrupted.i5Heater temperature control problem.IGNITION FAULTGas valve return signal was lost during DSI proof time and retry count has been satisfied…Invalid dryer door circuit stateInvalid dryer door circuit stateLLow L2 voltage (less than 50V) detected at the CCU; displayed on models 4000 and 3000.L2Low L2 voltage (less than 50V) detected at the CCU; displayed on model 4200.LINT ACCESS OPENThe lint drawer is open and needs to be closed.Low voltageLow voltage condition detected (below approximately 90 VAC).LOW VOLTAGE FAULTPower has dropped below the operating values and the system will shutdown.Lower dryer door sense errorLower dryer door sense error on control board or due to power line interferenceMAIN DOOR OPENEDA main door is open when it should be closed.MODEL ERRORThe wrong model was selected for the dryer.MODEL ERROR, ENTER CORRECT MODELController detected input signals (sail switch, gas valve) that do not match the…MSMotor sense error on control board or due to power line interference (cycles and customer…oPThermistor is open (infinite resistance) or temperature near thermistor has fallen below…OPEN EXHAUST TEMPERATURE PROBEThe exhaust temperature probe is open or shorted.OPEN S.A.F.E. SYSTEM PROBE FAULTThe temperature probe for the S.A.F.EOPEN THERMISTOR PROBES.A.F.EPFA power failure occurred during an active or paused cycle.PUSHAmount to start has been inserted; ready for temperature selection and start.ROTATION FAULTThe basket (tumbler) is not rotating.ROTATION SENSOR FAULTTime between rotational sensor pulses exceeded 10 seconds, indicating basket (tumbler) is…S.A.F.E. SYSTEM ACTIVATEDControl has detected a fire in the basket (tumbler) and is currently extinguishing the…S.A.F.E. SYSTEM DISABLED READYA fault has been detected in the S.A.F.ES.A.F.E. SYSTEM WAS ACTIVATEDControl detected a fire and has completed extinguishing the flame.SAIL SWITCH CLOSED FAULTSail switch is in the closed position at startup or restart; the controller allowed 10…SAIL SWITCH OPEN FAULTSail switch did not close within 8 seconds of starting/restarting, or opened for more…SEFLRotational sensor circuit failure indicating a fault in the basket (tumbler) rotation…SHThermistor is shorted (zero ohms resistance) or temperature near thermistor is above…SHORTED THERMISTOR PROBES.A.F.ESHORTED WATER VALVES.A.F.ETRACExhaust thermistor open-temperature drops below 18°F (>50 kΩ) for 1 minute in Run mode…tSDryer thermistor short sensed-the thermistor resistance is very low (display fault code).Upper dryer motor control circuit errorUpper dryer motor control circuit errorUpper dryer motor sense circuit errorUpper dryer motor sense circuit error on control board or due to power line interferenceWATER NOT CONNECTEDNo water pressure at the S.A.F.E

Get the full diagnostic procedure for any code

Step-by-step tests, expected values, wiring diagram references, and verified part numbers.

Get Started $9.95 3-day pass

$29/month for all brands and Max diagnostics, with 70 Max messages a day. Plus applicable tax.