Skip to main content
Error code reference
Kenmore Washer Error Codes
115 error codes documented with diagnostic procedures.
Have your model number? Get codes specific to your unit.
CAAverage current limit trip occurring when there is a 2-second average of current draw…CECommunications error indicating a breakdown in communication between the machine…CIInstantaneous current limit trip occurring when there is a spike of 26 Amps instantly at…CLControl Lock is active; displayed alternately with the estimated time remaining when…dEDoor open errordLDoor Lid Lock FailuredUDoor Unlock FailureE11Fill time too longE13Water leak in tub or air leak in air bell.E14Reed switch faultE21Water not pumping out fast enough.E23Drain pump relay on control board failed.E24Drain pump relay on control board failed.E31Better modelsE35Better modelsE41Control board thinks the door switch is open.E42Door remains locked after cycle is completed.E43Board communications problem.E44Board communications problem.E45Board communications problem.E46Board communications problem.E47Board thinks the door PTC circuit is open in spin.E48Board thinks the door PTC circuit is closed.E52Bad signal from tacho generator.E55Motor overheating.E56High motor current.E57High current on inverter.E58High current on motor phase.E59No tacho signal for 3 seconds.E5AHigh temperature on heat sink.E5BHigh temperature on heat sink.E5CHigh temperature on heat sink.E5DCommunication problem between control board and speed control board.E5ECommunication problem between control board and speed control board.E5FCommunication problem between control board and speed control board.E67Input voltage on microprocessor incorrect.E75Better models onlyE76Better models onlyE95Communication error.EB1Incoming power frequency out of limits.EB2Incoming line voltage above 130 VAC.EB3Incoming line voltage below 90 VAC.EEEEPROM errorEF1Clogged drain pump.EF2Too much detergent / oversudsing.EF5Better models onlyErProcessor reset error displayed when the control failed to save cycle information during…F/02Long drain time; if drain time exceeds 8 minutes the water valves are turned offF/05Water temperature sensor (NTC) value is out of range during the water heating step in the…F/06Drive motor tachometer error; the control is unable to properly detect motor speed and…F/07Motor Control Unit (MCU) error; the main control has detected a short in the MCUF/09Overflow condition; the overflow contact on the pressure switch is closed for more than…F/10Motor Control Unit (MCU) heat sink thermal tripF/11Serial communication errorF/13Dispenser circuit errorF/14EEPROM error; the CCU cannot properly read data from the onboard EEPROMF/15Motor Control Unit (MCU) errorF/21CCU/touch-pad/LED assembly communication error; the touch-pad/LED assembly is not able to…F/22CCU/touch-pad/LED assembly communication error (same as F/21); the touch-pad/LED assembly…F/23Heater failureF/25Drive motor tachometer errorF/29Door unlock errorF/33Pump drive system errorF/HNo water detected entering the machine or pressure switch not tripping; valves turn off…F01No water detected entering machine or pressure switch trip not detected after flow meter…F1Pressure Signal Out-of-Range-control detects an out of range pressure signal.F2Keypad/User Interface FailureF20No water detected entering machine or pressure switch trip not detectedF24Water temperature sensor errorF26Door switch errorF27Overflow conditionF28Serial communication errorF30Dispenser system errorF31MCU failureF32Pressure switch failureF34Analog pressure sensor failureF35Analog pressure sensor failureF40ATC Thermistor Open/ShortF41Motor RPS Thermistor Open/ShortF42Motor control unit failure, repetitive undervoltageF50Motor StalledF51Motor RPS FailureF52Motor Stop FailureF53Motor Control OvertempF54Motor control over-current faultF72Basket Re-engagement FailureFdLDoor lock errorFdUDoor unlock errorFEOverflow error; water level has exceeded the expected level.FLOverfill condition where excessive water in the tub causes the flood switch to trip; the…HCHot, Cold ReversedHEHeating errorIEWater inlet errorLdLong drain condition where it takes longer than 5 minutes to pump out water to a point…LELocked motor errorLFLong FilllidOpen/Close Door LidLoControl Lock is active; displayed when attempting to wake up a locked unit between cycles.LSLid switch error indicating the control cannot detect the lid switch opening/closing…obOff balance condition detected by the motor controller as an unrecoverable off-balance…OEWater is not completely drained within 12 minutes; drainage error.OFOverflow error-water is overflowing (water level frequency is over 213)oLOverloadedOROpen relay failure; the machine controller relay failed in the open position, preventing…PEPressure sensor errorPFPower failure detected during a running cycle; the washer does not flash PF when first…PoPump Out (lid opened)rLCleaning cycle unload indicationSdSuds lockSLSuds lock condition where suds are detected but the unit is unable to clean out suds…SRStuck relay failure; the machine controller relay failed in the closed position…SudExcessive suds detected; the MCU senses a suds lock condition by analyzing current draw…tEHeating error-the thermistor is out of order.UEUnbalance error-the load is too small, the appliance is tilted, laundry is gathered to…uLUnbalanced Load
Get the full diagnostic procedure for any code
Step-by-step tests, expected values, wiring diagram references, and verified part numbers.
Get Started $9.95 3-day pass$29/month for all brands and Max diagnostics, with 70 Max messages a day. Plus applicable tax.