Skip to main content
Error code reference
Electrolux Dryer Error Codes
187 error codes documented with diagnostic procedures.
Have your model number? Get codes specific to your unit.
0x21Condense Pump Error-Wiring defective or Pump defective or Main Board defective.0x22Condense Pump Sensing Error-Main Board defective.0x31Conductimetric Sensor Frequency Too High-Wiring defective or Main Board defective.0x32Conductimetric Sensor Frequency Too Low-Wiring defective or Main Board defective.0x45Door Closed Sensing Error-Main Board defective.0x55FCV Safety Error-Main Board defective.0x56FCV Motor Plug Not Connected-Wiring defective or Motor defective or Main Board defective.0x57FCV Current Trip Failure-Wiring defective or Motor defective or Main Board defective.0x58FCV Over Current Failure-Wiring defective or Motor defective or Main Board defective.0x59FCV Motor Not Following-Main Board defective.0x5AFCV Board Overheating-Wiring defective or Motor defective or Main Board defective.0x5BFCV Under Voltage Failure-Power supply problem or main board defective.0x5CFCV Over Voltage Failure-Power supply problem or main board defective.0x5DFCV Unknown Message Error-Main Board defective.0x5FFCV Power Module Error-Main Board defective.0x62Heater Short Circuit Error-Heater Relay stuck open or closed or Wiring defective or…0x63Heater Error-Heater Relay stuck open or closed or Wiring defective or Main Board…0x64Heater Sensing Error-Main Board defective.0x71Drying NTC Error-NTC1 failure or Wiring defective or Main Board defective.0x72Heater NTC Error-NTC2 failure or Wiring defective or Main Board defective.0x73Steamer NTC Error-NTC2 failure or Wiring defective or Main Board defective.0x83Selector Position Code Error-User Interface Board defective.0x86Selector Configuration Table Error-User Interface Board defective.0x87UI Board Microcontroller Self Test Failure-User Interface Board defective.0x91User Interface Communication Error-User Interface Board defective or Main Board defective…0x92User Interface Protocol Incongruence Error-Main Board incompatible with User Interface…0x93Machine Configuration Checksum Error-Wrong configuration data loaded, User Interface…0x94Cycle Configuration Checksum Error-Wrong configuration data loaded or Main Board…0x97Missing Program on CTF Error-Discrepancy between programme configuration data and…0x9CUser Interface Configuration Checksum Error-Discrepancy between programme configuration…0x9EUser Interface Touch Sensor Not Working-Humidity or Water on User Interface Board or User…0xB1Power Supply Frequency Out of Range-Power Supply Frequency out of configured range.0xB2Power Supply Amplitude Out of Range (Too High)-Line Voltage too high or Main Board fault.0xB3Power Supply Amplitude Out of Range (Too Low)-Line Voltage too Low or Main Board fault.0xB4Zero Watt Relay Error-Line Connections in home faulty, Wiring or Main Board defective.0xBDLine Safe Short Circuit Error-Main Board defective.0xBELine Safe Error-Main Board defective.0xBFLine Safe Sensing Error-Main Board defective.0xF6Safety Reset Error-Main Board defective.34Capacitive sensor values read by main control board are not within the predefined…35Capacitive sensor assembly communication problem with main control board (500 and 600…41Door opened at cycle start.42Door closed sensing error.51Drum motor relay error52Drum motor start sensing error53Drum motor centrifugal switch error54Drum motor sensing error61Heater relay error.63Heater short error.64Heater open error.65Thermostat open67Heater sensing error71NTC1 open error72NTC1 (SHORTED) error.73NTC2 open error74NTC2 (SHORTED) error.91User Interface communication problem with main board.92User Interface mother board protocol mismatch.93MCF checksum error94CCF checksum error97Missing program on CTF error9CUser Interface configuration checksum error9EUser Interface touch sensor not workingAL 50The motor has been overloaded.AL 97There is a disruption in internal communication between electronic elements of the unit.AL H0There is an issue with the power supply.B1Power supply frequency out of range.B2Power supply amplitude out of range (too HIGH voltage).B3Power supply amplitude out of range (too LOW voltage).B4Line wiring errorBDLine safe relay short circuit error.BELine safe errorBFLine safe sensing errorC9Communication circuit between the main board and the display board is damaged, or PCB…DEMO MODEDryer has been programmed to temporarily perform a repeating demo cycle instead of normal…E00No failure code experienced; indicates no error has been recorded.E10Problem with communication between EEPROM and the microprocessor.E11Problem with communications or memory did not check, one has become corrupted (Checksum…E12Problem reading or writing to the memory or input/output (Non fatal R/W error).E21Condensate pump triac defective.E22Condense pump sensing alarm (ENV06 platform)E24Control thermistor or its wiring is shorted (Control NTC Short Circuit).E25Control thermistor or its wiring is open (Control NTC Open Circuit).E31Contact Sensor frequency too high, indicating Electronic Control Board defective or…E32Contact Sensor frequency too low, indicating Electronic Control Board defective or…E33Displayed in the last alarm if diagnostics position 8 is NOT OK (conductimetric sensor…E4Humidity sensor detecting circuit (circuit and components) on the main control board is…E41Door opening solenoid supply triac defective.E42Sensing circuit of the door opening solenoid supply triac defective.E43Incongruency of the sensing signal of the door interlock.E45Door closure sensor fault.E4AClogged vent or restricted airflow detected, resulting in longer than normal drying times.E5Outlet temperature sensor error (A/D reading under 10 indicating open, or over 1000…E51Drum motor relay errorE52Drum motor thermal cut-off alarm (ENV06)E53Exhaust thermal limiter has tripped (open fuse), indicating possible airflow restriction…E54Motor jammed alarm (ENV06)E57Inverter is drawing too much current (>15 A)E58Inverter is drawing too much current (>4.5 A)E59No signal from tachometric generator for 3 secondsE5AOverheating on cooling dissipater for inverter (>88°C)E5BTemperature reading of control thermistor has not changed in a certain amount of time…E5CInput voltage is too highE5dData transfer error between inverter and main PCBE5ECommunication error between inverter and main PCBE5FInverter PCB fails to start the motorE5HInput voltage is lower than 175 VE61Heater relay errorE62Heaters relay failure / compressor relay failure (ENV06)E63Heater to Earth GroundE64Heater Open Circuit-heating element or wiring defective with open circuit.E65High Limit Thermostat trip count too high due to high vent restriction, defective High…E66Thermal Limiter Open Circuit-Outlet Thermal Limiter tripped, Inlet Thermal Limiter…E67Heaters Sensing FailureE68Key (button) is stuck closed (active)E71Drying NTC1 alarmE72Outlet Control Thermistor short circuit-thermistor or wiring defective.E73NTC 2 (Inlet Control Thermistor) open, disconnected, or main board fault.E74Motor Relay failure-motor relay stuck open or closed, or wiring defective.E81Error at the reset position of the program selector.E82Communication error between main electronics and display/control electronics.E83Selector positions wrong.E8CThe safety (high limit) thermostat has tripped too many times within a certain period of…E91Communication Error between Electronic Control Board and Interface Board due to defective…E92User interface protocol incongruence errorE93Configuration alarm-machine configuration file missing or wrong cycle configuration file…E94CCF checksum alarmE95Communication error between microprocessor and EEPROM.E97Missing program on CTF errorE9CUser interface configuration checksum errorE9EUser interface touch sensor not workingEA1Main Supply Frequency out of Range-line frequency out of limits or Electronic Control…EA2Voltage too high-line voltage too high or Electronic Control Board faulty.EA3Voltage too low-line voltage too low or Electronic Control Board faulty.EA4Improper home wiringEA5Main Voltage Sensing failure due to defective Electronic Control Board.EAFMicrocontroller has been reset by internal Watchdog timer (Watch Dog Reset).EB1Mains supply frequency outside acceptable limits.EB2Mains supply frequency too high.EB3Mains supply frequency too low.EBDLine safe relay short circuit errorEBELine safe errorEBFLine safe sensing errorEC1Voltage incongruence between boards.EC2Frequency incongruence between boards.EC3CRM resistance out of time (only in diagnostic mode).EC4Steam generator (CRM) heater relay fault.EC5CRM thermostat faulty.EC6CRM piloting faulty.EC7CRM pump triac fault.EC8CRM pump diode short-circuited.EC9CRM pump piloting faulty.ECAWater tank empty.EF1Ventilation blocked errorEF3Max Timeout Timer-exhaust blocked, or defective Exhaust Control Thermistor, Inlet Control…EF6Safety reset errorEF8Key StuckEH1Power supply frequency out of rangeEH2Power supply voltage out of range (too HIGH)EH3Power supply voltage out of range (too LOW)EH4Line wiring errorErrError displayed when attempting to change a programme or option after the cycle has…F 01An internal fault in the electronic control board.F 02Control temperature sensor open or shorted.F 03No heatF 04The drying time has exceeded the program time for that cycle.F 05A problem with the keypad.F1Ventilation blocked errorF3No Gas Error.F6Safety reset errorH1Power supply frequency out of range.H1/B1Power supply frequency out of range.H2Power supply amplitude out of range (too HIGH voltage).H2/B2Power supply amplitude out of range (too HIGH).H3Power supply amplitude out of range (too LOW voltage).H3/B3Power supply amplitude out of range (too LOW).H4Line wiring errorH4/B4Line wiring error.HALine safe relay short circuit error.HA/BDLine safe relay short circuit error.HELine safe errorHE/BELine safe error.HFLine safe sensing errorHF/BFLine safe sensing error.LOCControl lock is activated.PAUCycle has been interrupted/paused.PFA power failure to the control board has occurred.
Get the full diagnostic procedure for any code
Step-by-step tests, expected values, wiring diagram references, and verified part numbers.
Get Started $9.95 3-day pass$29/month for all brands and Max diagnostics, with 70 Max messages a day. Plus applicable tax.