Carrier HVAC Error Code 46
Brownout condition: secondary voltage of the transformer has fallen below 15Vac for a period exceeding four seconds.
SourceFan Coil Units - Service Manual: Residential Fan Coil Units (FB4, FE4, FF1E, FFM, FH4, FV4, FX4, ...p. 16
Diagnostic procedure
The full 46 procedure
Step 1 is visible so you can confirm you are on the right page. The remaining steps, the ones that tell you whether to actually replace a part, unlock with any pass.
MyPros+ · DiagnosticsStep 1 preview
1
First diagnostic step
Check transformer input and output voltages. Condition clears automatically when secondary voltage rises above 17Vac for more than four seconds.
SourceFan Coil Units - Service Manual: Residential Fan Coil Units (FB4, FE4, FF1E, FFM, FH4, FV4, FX4, ...p. 16
More steps, wiring diagram references, and verified part numbers
Includes expected resistance and voltage values, connector pinouts, and supersession notes for replacement parts.